CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE
View Log Transaction
Press ‘4’ to select [4-View Lg] menu from Database Menu.
This menu item is to view the transactions logged. Use ‘A’ and ‘D’ keys to scroll through
the transaction log. To exit, press the ‘ESC’ key.
The Following Table Lists the Transaction Codes:
Description Transaction
Code
Valid Entry Access 0
Anti-Passback
Violation
1
UnknownCard
Number
2
Wrong Facility Code 3
Reader Reset 4
Reader Up 5
Reader Down 6
Controller Reset 7
Enter Program Mode 8
Exit Program Mode 9
Memory Cleared A
Reset Anti-Passback B
Manual Lock Release C
Wrong PIN Password D
Door Left Open E
Door Closed F
Door Forced Open G
Card Lock Out H
Reset Lock Out I
Wrong Time Zone J
Duress Alarm K
Door Interlocked L
Alarm ON M
Alarm OFF N
Door Security O
Alarm Delay Arm Start P
Alarm Armed Q
Alarm Trigger R
Alarm Disarm S
Alarm Isolated T
Output ON U
Output OFF V
Output Isolated W
Input ON X
Input OFF Y
Change PIN Z
Valid PIN Access a
Card Disable b
Card Enable c
Pulse Door Open d
Door Open e
Invalid PIN Access f
Inactive Card g
Card Expired h
Valid Exit Access i
Cold Start j
Mains Fail s
Mains Normal t
Power Low u
Power Normal v
Temper On r
Door Security On k
Door Security Off l
Clear Card Database
Press ‘5’ key to select [5-Clr DB] menu from Database Menu.
This menu item it to delete all the cards installed in the controller.
After press ‘5’ at Database Menu, the controller will display as follow: -
The controller will prompt the user to confirm to clear the card database. If the
user confirm to clear the database, he/she just has to press ‘ENT’ key. The
controller will clear all the database in the controller.
To cancel ‘Clear Card Database’, press ‘ESC’ key.
CASS TECHNOLOGY SDN BHD(338857-X) 29
dd/mm DDD hh:mm:ss
Clear Card (Y=ENT) ?