CASTLE COMMANDO SERIES CONTROLLER – TECHNICAL OPERATION GUIDE
g. Card + PIN TimeZone
A value of 00-255 is allowed. This item is used to set the reader to prompt the card
user for PIN number after the user swipe a valid card. This option will be activated
within the TimeZone setting.
h. Exit Button TimeZone
A value of 00-255 is allowed. This item is used to set or specify a time zone for door
exit push button to activate. User only can only exit through the door during the time
zone.This option will be activated within the TimeZone setting.
i. Emergency Mode
A value of 1-3 is allowed. This setting can only be used when the controller is down.
The reader will follow the setting at the controller and will operate independently.
The default value is set to 1.
Below is the configuration setting of each number: -
Function
1 Lock Release
2 Facility Code
3 Auto-PIN
1 => The electric lock will automatically released when the controller is down.
2 => The reader will prompt user to swipe the card. It will release the lock when
the facility code of the card is valid.
3 => Only Auto-PIN that set at the Emergency PIN Mode in the Controller is
required.
i. Use Common PIN (Set the Common No. in Parameter Setting)
This item is used to set the reader to use the Auto-PIN number that set at the
controller or use the Local Auto-PIN number that to the specify door. This only can
be set to ON or OFF position.
CASS TECHNOLOGY SDN BHD(338857-X) 18
dd/mm DDD hh:mm:ss
Card + Pin Tz [000]
dd/mm DDD hh:mm:ss
Emergency Mode [ 3 ]
dd/mm DDD hh:mm:ss
Use Common Pin [ON]
dd/mm DDD hh:mm:ss
Exit Button Tz [001]